Review



interactive reconstruction algorithm 3-dimensional ordered subset expectation maximisation  (Sumitomo Dainippon)

 
  • Logo
  • About
  • News
  • Press Release
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 90

    Structured Review

    Sumitomo Dainippon interactive reconstruction algorithm 3-dimensional ordered subset expectation maximisation
    Interactive Reconstruction Algorithm 3 Dimensional Ordered Subset Expectation Maximisation, supplied by Sumitomo Dainippon, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/ordered-subset+expectation+maximisation+algorithm/interactive+reconstruction+algorithm+3+dimensional+ordered+subset+expectation+maximization/pmc11564661-120-32-42
    Average 90 stars, based on 1 article reviews
    interactive reconstruction algorithm 3-dimensional ordered subset expectation maximisation - by Bioz Stars, 2026-11
    90/100 stars

    Images

    Related Articles

    other:

    Article Title: (R)-[¹¹C]Emopamil as a novel tracer for imaging enhanced P-glycoprotein function.
    Article Snippet: ⁎ Corresponding author at: Research Team for Neuroim tute of Gerontology, 35-2 Sakae-cho, Itabashi-ku, Tokyo 17 3241; fax: +81 3 3964 2188.. E-mail address: toyohara@pet.tmig.or.jp (J. Toyohara) http://dx.doi.org/10.1016/j.nucmedbio.2015.09.001 0969-8051/© 2015 Elsevier Inc. All rights reserved.. Article history: Received 27 June 2015 Received in revised form 31 August 2015 Accepted 3 September 2015

    Positron Emission Tomography:

    Article Title: Light up heart-type fatty acid binding protein (FABP3) with a novel fluorine-18 labelled selective FABP3 ligand
    Article Snippet: .. PET scanning was started at 30 min after injection and conducted for 20 min. Data collected 30–50 min after injection of [ 18 F]LUF were reconstructed in a single frame using an interactive reconstruction algorithm (3-dimensional ordered subset expectation maximisation, provided by Sumitomo Heavy Industries; 1 iteration, 32 subsets). ..

    Injection:

    Article Title: Light up heart-type fatty acid binding protein (FABP3) with a novel fluorine-18 labelled selective FABP3 ligand
    Article Snippet: .. PET scanning was started at 30 min after injection and conducted for 20 min. Data collected 30–50 min after injection of [ 18 F]LUF were reconstructed in a single frame using an interactive reconstruction algorithm (3-dimensional ordered subset expectation maximisation, provided by Sumitomo Heavy Industries; 1 iteration, 32 subsets). ..



    Similar Products

    90
    Sumitomo Dainippon interactive reconstruction algorithm 3-dimensional ordered subset expectation maximisation
    Interactive Reconstruction Algorithm 3 Dimensional Ordered Subset Expectation Maximisation, supplied by Sumitomo Dainippon, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/ordered-subset+expectation+maximisation+algorithm/interactive+reconstruction+algorithm+3+dimensional+ordered+subset+expectation+maximization/pmc11564661-120-32-42
    Average 90 stars, based on 1 article reviews
    interactive reconstruction algorithm 3-dimensional ordered subset expectation maximisation - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Siemens Healthineers ordered subset expectation maximisation (osem) algorithm truex
    Ordered Subset Expectation Maximisation (Osem) Algorithm Truex, supplied by Siemens Healthineers, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/ordered-subset+expectation+maximisation+algorithm/osem3d+algorithm/pm33715090-57-7-13
    Average 90 stars, based on 1 article reviews
    ordered subset expectation maximisation (osem) algorithm truex - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Philips Healthcare relaxed list mode ordered subset expectation maximisation (lmosem) algorithm
    Relaxed List Mode Ordered Subset Expectation Maximisation (Lmosem) Algorithm, supplied by Philips Healthcare, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/ordered-subset+expectation+maximisation+algorithm/relaxed+list+mode+ordered+subset+expectation+maximisation++lmosem++algorithm/pmc08316557-146-10-23
    Average 90 stars, based on 1 article reviews
    relaxed list mode ordered subset expectation maximisation (lmosem) algorithm - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    MILabs similarity-regulated ordered-subsets expectation maximisation algorithm (srosem)
    Contrast-to-noise ratio (CNR) of the investigated collimators with optimized values for each rod size by Gaussian post-filtering (full width half maximum = rod size). Bar charts compare the image quality of the collimators XUHR-M, GP-M and UHS-M for different activity levels in the mini Derenzo phantoms 850.500 and 850.100. In addition, the graphs in ( c ), ( e ) and ( g ) show how the 3DT-Scanner with the same GP-M collimator and a pixel-based ordered-subset expectation <t>maximisation</t> (POSEM) reconstruction algorithm compares to the new 2DT-Scanner and the similarity-regulated ordered-subset expectation maximisation <t>(SROSEM)</t> algorithm. Time per bed position (TPB) was 300 s with at least 9 bed positions (BP), corresponding to a total scan duration of 45 min
    Similarity Regulated Ordered Subsets Expectation Maximisation Algorithm (Srosem), supplied by MILabs, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/ordered-subset+expectation+maximisation+algorithm/similarity+regulated+ordered+subsets+expectation+maximisation+algorithm++srosem+/pmc07606439-50-9-20
    Average 90 stars, based on 1 article reviews
    similarity-regulated ordered-subsets expectation maximisation algorithm (srosem) - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Siemens Healthineers 3d-iterative ordinary poisson ordered-subsets expectation maximisation (op-osem3d) reconstruction algorithm
    Contrast-to-noise ratio (CNR) of the investigated collimators with optimized values for each rod size by Gaussian post-filtering (full width half maximum = rod size). Bar charts compare the image quality of the collimators XUHR-M, GP-M and UHS-M for different activity levels in the mini Derenzo phantoms 850.500 and 850.100. In addition, the graphs in ( c ), ( e ) and ( g ) show how the 3DT-Scanner with the same GP-M collimator and a pixel-based ordered-subset expectation <t>maximisation</t> (POSEM) reconstruction algorithm compares to the new 2DT-Scanner and the similarity-regulated ordered-subset expectation maximisation <t>(SROSEM)</t> algorithm. Time per bed position (TPB) was 300 s with at least 9 bed positions (BP), corresponding to a total scan duration of 45 min
    3d Iterative Ordinary Poisson Ordered Subsets Expectation Maximisation (Op Osem3d) Reconstruction Algorithm, supplied by Siemens Healthineers, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/ordered-subset+expectation+maximisation+algorithm/osem3d+algorithm/10__1097_slash_mnm__0000000000001035-52-5-29
    Average 90 stars, based on 1 article reviews
    3d-iterative ordinary poisson ordered-subsets expectation maximisation (op-osem3d) reconstruction algorithm - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Philips Healthcare blob-based ordered-subset expectation maximisation algorithm
    Contrast-to-noise ratio (CNR) of the investigated collimators with optimized values for each rod size by Gaussian post-filtering (full width half maximum = rod size). Bar charts compare the image quality of the collimators XUHR-M, GP-M and UHS-M for different activity levels in the mini Derenzo phantoms 850.500 and 850.100. In addition, the graphs in ( c ), ( e ) and ( g ) show how the 3DT-Scanner with the same GP-M collimator and a pixel-based ordered-subset expectation <t>maximisation</t> (POSEM) reconstruction algorithm compares to the new 2DT-Scanner and the similarity-regulated ordered-subset expectation maximisation <t>(SROSEM)</t> algorithm. Time per bed position (TPB) was 300 s with at least 9 bed positions (BP), corresponding to a total scan duration of 45 min
    Blob Based Ordered Subset Expectation Maximisation Algorithm, supplied by Philips Healthcare, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/ordered-subset+expectation+maximisation+algorithm/blob+based+ordered+subset+expectation+maximisation+algorithm/pmc06647179-66-7-13
    Average 90 stars, based on 1 article reviews
    blob-based ordered-subset expectation maximisation algorithm - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Siemens AG ordered-subset expectation maximisation algorithm
    Contrast-to-noise ratio (CNR) of the investigated collimators with optimized values for each rod size by Gaussian post-filtering (full width half maximum = rod size). Bar charts compare the image quality of the collimators XUHR-M, GP-M and UHS-M for different activity levels in the mini Derenzo phantoms 850.500 and 850.100. In addition, the graphs in ( c ), ( e ) and ( g ) show how the 3DT-Scanner with the same GP-M collimator and a pixel-based ordered-subset expectation <t>maximisation</t> (POSEM) reconstruction algorithm compares to the new 2DT-Scanner and the similarity-regulated ordered-subset expectation maximisation <t>(SROSEM)</t> algorithm. Time per bed position (TPB) was 300 s with at least 9 bed positions (BP), corresponding to a total scan duration of 45 min
    Ordered Subset Expectation Maximisation Algorithm, supplied by Siemens AG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/ordered-subset+expectation+maximisation+algorithm/ordered+subset+expectation+maximization+algorithm/pmc06647179-66-23-29
    Average 90 stars, based on 1 article reviews
    ordered-subset expectation maximisation algorithm - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Philips Healthcare ordered-subsets expectation maximisation (osem) algorithm with butterworth lowpass filter
    Contrast-to-noise ratio (CNR) of the investigated collimators with optimized values for each rod size by Gaussian post-filtering (full width half maximum = rod size). Bar charts compare the image quality of the collimators XUHR-M, GP-M and UHS-M for different activity levels in the mini Derenzo phantoms 850.500 and 850.100. In addition, the graphs in ( c ), ( e ) and ( g ) show how the 3DT-Scanner with the same GP-M collimator and a pixel-based ordered-subset expectation <t>maximisation</t> (POSEM) reconstruction algorithm compares to the new 2DT-Scanner and the similarity-regulated ordered-subset expectation maximisation <t>(SROSEM)</t> algorithm. Time per bed position (TPB) was 300 s with at least 9 bed positions (BP), corresponding to a total scan duration of 45 min
    Ordered Subsets Expectation Maximisation (Osem) Algorithm With Butterworth Lowpass Filter, supplied by Philips Healthcare, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/ordered-subset+expectation+maximisation+algorithm/ordered+subsets+expectation+maximisation++osem++algorithm+with+butterworth+lowpass+filter/10__1080_slash_21681163__2018__1501768-56-15-25
    Average 90 stars, based on 1 article reviews
    ordered-subsets expectation maximisation (osem) algorithm with butterworth lowpass filter - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Sumitomo Dainippon iterative reconstruction algorithm 3-dimensional ordered-subset expectation maximisation
    Contrast-to-noise ratio (CNR) of the investigated collimators with optimized values for each rod size by Gaussian post-filtering (full width half maximum = rod size). Bar charts compare the image quality of the collimators XUHR-M, GP-M and UHS-M for different activity levels in the mini Derenzo phantoms 850.500 and 850.100. In addition, the graphs in ( c ), ( e ) and ( g ) show how the 3DT-Scanner with the same GP-M collimator and a pixel-based ordered-subset expectation <t>maximisation</t> (POSEM) reconstruction algorithm compares to the new 2DT-Scanner and the similarity-regulated ordered-subset expectation maximisation <t>(SROSEM)</t> algorithm. Time per bed position (TPB) was 300 s with at least 9 bed positions (BP), corresponding to a total scan duration of 45 min
    Iterative Reconstruction Algorithm 3 Dimensional Ordered Subset Expectation Maximisation, supplied by Sumitomo Dainippon, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/ordered-subset+expectation+maximisation+algorithm/interactive+reconstruction+algorithm+3+dimensional+ordered+subset+expectation+maximization/pm26429767-247-10-18
    Average 90 stars, based on 1 article reviews
    iterative reconstruction algorithm 3-dimensional ordered-subset expectation maximisation - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Siemens AG 3d ordered-subset expectation-maximisation algorithm ‘flash-3d
    Contrast-to-noise ratio (CNR) of the investigated collimators with optimized values for each rod size by Gaussian post-filtering (full width half maximum = rod size). Bar charts compare the image quality of the collimators XUHR-M, GP-M and UHS-M for different activity levels in the mini Derenzo phantoms 850.500 and 850.100. In addition, the graphs in ( c ), ( e ) and ( g ) show how the 3DT-Scanner with the same GP-M collimator and a pixel-based ordered-subset expectation <t>maximisation</t> (POSEM) reconstruction algorithm compares to the new 2DT-Scanner and the similarity-regulated ordered-subset expectation maximisation <t>(SROSEM)</t> algorithm. Time per bed position (TPB) was 300 s with at least 9 bed positions (BP), corresponding to a total scan duration of 45 min
    3d Ordered Subset Expectation Maximisation Algorithm ‘Flash 3d, supplied by Siemens AG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/ordered-subset+expectation+maximisation+algorithm/3d+ordered+subset+expectation+maximisation+algorithm++flash+3d/pmc04182457-67-10-14
    Average 90 stars, based on 1 article reviews
    3d ordered-subset expectation-maximisation algorithm ‘flash-3d - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    Image Search Results


    Contrast-to-noise ratio (CNR) of the investigated collimators with optimized values for each rod size by Gaussian post-filtering (full width half maximum = rod size). Bar charts compare the image quality of the collimators XUHR-M, GP-M and UHS-M for different activity levels in the mini Derenzo phantoms 850.500 and 850.100. In addition, the graphs in ( c ), ( e ) and ( g ) show how the 3DT-Scanner with the same GP-M collimator and a pixel-based ordered-subset expectation maximisation (POSEM) reconstruction algorithm compares to the new 2DT-Scanner and the similarity-regulated ordered-subset expectation maximisation (SROSEM) algorithm. Time per bed position (TPB) was 300 s with at least 9 bed positions (BP), corresponding to a total scan duration of 45 min

    Journal: EJNMMI Physics

    Article Title: Performance evaluation of fifth-generation ultra-high-resolution SPECT system with two stationary detectors and multi-pinhole imaging

    doi: 10.1186/s40658-020-00335-6

    Figure Lengend Snippet: Contrast-to-noise ratio (CNR) of the investigated collimators with optimized values for each rod size by Gaussian post-filtering (full width half maximum = rod size). Bar charts compare the image quality of the collimators XUHR-M, GP-M and UHS-M for different activity levels in the mini Derenzo phantoms 850.500 and 850.100. In addition, the graphs in ( c ), ( e ) and ( g ) show how the 3DT-Scanner with the same GP-M collimator and a pixel-based ordered-subset expectation maximisation (POSEM) reconstruction algorithm compares to the new 2DT-Scanner and the similarity-regulated ordered-subset expectation maximisation (SROSEM) algorithm. Time per bed position (TPB) was 300 s with at least 9 bed positions (BP), corresponding to a total scan duration of 45 min

    Article Snippet: For reconstruction of the created list-mode data, the similarity-regulated ordered-subsets expectation maximisation algorithm (SROSEM), as provided with the dedicated software (MILabs.Rec Version 8.06) of the 2DT-Scanner system, was used [ ].

    Techniques: Activity Assay